Datatek DT-6061 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Procesory Datatek DT-6061. Datatek DT-6061 User`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 72
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
DT-6061
Embedded Network Processor
Platform
User's Manual
RELEASE.VERSION 17.1
379 Campus Drive, Suite 100
Somerset, NJ 08873
fax: 732 667-1091
phone: 732 667-1080
http://www.datatekcorp.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - ELEASE.VERSION 17.1

DT-6061 Embedded Network Processor Platform User's Manual RELEASE.VERSION 17.1 379 Campus Drive, Suite 100 Somerset, NJ 08873 fax: 732 6

Strona 2 - TABLE OF CONTENTS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 10 Application Name Description X25PAD Eliminates the need

Strona 3

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 11 2 PHYSICAL DESCRIPTION Figure 2: DT-6061 Front View 2.

Strona 4

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 12 2.4 10BASE-T LAN These two interfaces require a standar

Strona 5 - TABLE OF FIGURES AND TABLES

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 13 3 INSTALLATION This chapter contains the steps required

Strona 6

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 14  DT-6061 unit(s)  AC to DC power supply(s). –48 VDC i

Strona 7 - Save These Instructions

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 15 5) Attach console cable by plugging 1 end of the RJ45

Strona 8 - 1 INTRODUCTION

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 16 4 CABLING 4.1 SERIAL CONSOLE CONNECTION AND CONFIGURATI

Strona 9 - ULTIPLE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 17 Important! A modular cable with “SPECIAL WIRING” can

Strona 10 - VAILABILITY

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 18 5 QUICK S TART C ONFIGURATION G UIDE There are two leve

Strona 11 - 2 PHYSICAL DESCRIPTION

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 19 5.3 APPLICATION INSTALLATION This action requires that

Strona 12

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 2 TABLE OF CONTENTS TABLE OF CONTENTS ...

Strona 13 - down view

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 20 6 DT-6061 C OMMAND R EFERENCE All DT-6XXX software is

Strona 14

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 21  The banner and some of the parameters of the snmp com

Strona 15

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 22 Table 5: Command Reference table Section NumberCategory

Strona 16 - 4 CABLING

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 23 6.3 SYSTEM PLATFORM CONFIGURATION – NON IP NETWORK COMM

Strona 17 - ONNECTIONS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 24 a newline (enter). The user is again prompted for a lin

Strona 18 - OFTWARE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 25 6.3.7 CHANGE PASSWORD - CHGPASS Syntax: chgpass OLD=<

Strona 19

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 26 6.4 SYSTEM PLATFORM CONFIGURATION – IP NETWORK RELATED

Strona 20 - C OMMAND R EFERENCE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 27 The IP address and subnet mask are used to determine wh

Strona 21

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 28 The optional simplex parameter can be used to switch th

Strona 22

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 29 Each ipaddr<n> field is the IP address of a Domai

Strona 23

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 3 6.3.4 System Label Configuration - label...

Strona 24 - ATE AND

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 30  If a DT-4XXX or UMI at address 'C' has been

Strona 25

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 31 6.5 SOFTWARE ADMINISTRATION COMMANDS 6.5.1 INSTALLING A

Strona 26

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 32 If parameters are omitted from the command line, instal

Strona 27

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 33 (including its configuration). The type must be the nam

Strona 28

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 34 IP address of the DT-6061 or the configured label. The

Strona 29

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 35 non-volatile memory. There is only one trap=<commun

Strona 30

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 36 6.8 RUN-TIME COMMANDS 6.8.1 DISPLAY CONNECTIONS – DC OR

Strona 31 - DMINISTRATION

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 37 reports only connections that are associated with insta

Strona 32

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 38 The cpu subcommand reports CPU utilization by process.

Strona 33

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 39 sclk: 0 0% 113992 eth0: 132 0% 8912

Strona 34 - TILITIES

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 4 6.9.3 Automatic Standby Configuration Update – stby cfg.

Strona 35

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 40 6.8.3.6 TRACE ROUTE - DIAG TRACERT OR DIAG TRTE Syntax

Strona 36 - DC OR DCONN

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 41 destination. Each router along the path is required to

Strona 37 - DIAG CPU

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 42 The vfy cfg (or vfycfg) command displays each configure

Strona 38 - DIAG DEV

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 43 6.9 HIGH AVAILABILITY OPTION The High Availability opti

Strona 39 - DIAG PING

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 44 synchronizing, thus disabling the ability to switchover

Strona 40 - DIAG TRACERT OR DIAG TRTE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 45 standby software in sync with the active. The release n

Strona 41 - ETTINGS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 46 the active DT-6061. Either way, registration of the app

Strona 42 - VFY MOD OR VFYMOD

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 47  snmp  switchover  timeout  timezone The help comm

Strona 43

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 48 7 APPENDIX A: C ONSOLE C ABLE - S PECIAL W IRING D

Strona 44 - STBYUPD

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 49 7.1 THE DB9 CONSOLE ADAPTER Some Personal Computers us

Strona 45 - STBY CFG

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 5 14 End-User License Agreement for Software...

Strona 46

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 50 8 APPENDIX B: SNMP MIB VARIABLE D ATABASE AND T RAP

Strona 47

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 51 MIB Variable Number Name MIB Console Equivalent Acce

Strona 48 - PIN Numbering

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 52 MIB Variable Number Name MIB Console Equivalent Acce

Strona 49 - DB9 Async DCE Console Adapter

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 53 9 APPENDIX C: TCP/UDP P ORT N UMBERS The DT-6061 use

Strona 50 - D ATABASE AND T RAPS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 54 10 APPENDIX D: T HE D ISPLAY M EASUREMENTS ( DM) R

Strona 51

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 55 Measurement descriptions: IP 1: The total number of in

Strona 52 - UPPORTED

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 56 10.2 TCP – DM TCP <DT-6061> dm tcp tcp: TCP 1 12

Strona 53

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 57 TCP 12 2 connections dropped by rexmit timeout TCP 13

Strona 54 - EASUREMENTS ( DM) R EPORT

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 58 10.3 UDP – DM UDP <DT-6061> dm udp udp: 834716 da

Strona 55

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 59 10.4 ICMP – DM ICMP Note - within the output and inpu

Strona 56 - 10.2 TCP

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 6 Table 9: TCP/UDP Port Numbers Used ...

Strona 57

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 60 Measurement descriptions: ICMP 1: The number of ICMP m

Strona 58 - 10.3 UDP

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 61 10.5 ETH – DM ETH <tuna: DT-6061> dm eth Name

Strona 59 - 10.4 ICMP

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 62 11 APPENDIX E: B RIEF D ESCRIPTIONS OF DT-6XXX A PPL

Strona 60

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 63 LoopCare® product. The LoopCare product is the evolutio

Strona 61 - 10.5 ETH

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 64 maintenance. Finally, the physical location of these pr

Strona 62 - DT-6XXX A PPLICATIONS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 65 11.12 ONSITE The ONSITE application for the DT-6XXX Net

Strona 63 - 11.9 IP-SPOOL

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 66 12 APPENDIX F: DT-6061 S PECIFICATIONS Note: Shielded

Strona 64 - 11.11 MULTIMATE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 67 12.7 REGULATORY INFORMATION Safety: UL, CSA, Low Volta

Strona 65 - 11.12 ONSITE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 68 A representative designated by the supplier should coor

Strona 66

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 69 POWER REQUIREMENTS Voltages Current Draw Power Input Re

Strona 67 - NFORMATION

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 7 Important Safety Instructions The exclamation point with

Strona 68 - 12.7.3 NEBS

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 70 13 HARDWARE WARRANTY The warranty period for hardware s

Strona 69 - Power Input Requirements

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 71 14.3 SOFTWARE SUPPORT SOFTWARE support is not provided

Strona 70 - S OFTWARE

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 72 14.7 SPECIAL PROVISIONS The SOFTWARE and documentation

Strona 71

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 8 1 INTRODUCTION The DT-6061 (Embedded Network Processor)

Strona 72 - 15 LIMITATION OF L IABILITY

DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 9 1.1 MULTIPLE APPLICATION SUPPORT The DT-6061 can support

Komentarze do niniejszej Instrukcji

Brak uwag